KoolDuct's built-in radiant barrier

As most of the readers know KoolDuct is made up of a sandwich of foam between two layers of aluminum. The foam’s R-value is widely advertised and tested as exceeding the R6 and R8 required by most energy codes. What is never discussed is the possible effectiveness of the aluminum skin as radiant barrier!?

http://www.ornl.gov/sci/roofs+walls/radiant/rb_01.html

Here is the thought the foam insulation is designed to combat conductive heat (heat by physical contact) and convective heat (forced air) but the unthought-of form of heat flow is RADIATION.

htxfer101

To date I do not know of anyone who has consider the reflective benefits of KoolDuct on top of the convective and conductive properties of the foam. This snippet was just a starter for further discussion.

Currently rated 5.0 by 1 people

  • Currently 5/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

KD3z Design Software Nesting Tips

 

  1. Prioritize Fittings List
    1. Instead of importing with the .PNL file; Use the “Edit Parts List” and set the priority settings. Keep them in clusters (i.e. have fittings 1-3 as priory 1, next 2-6 priority 2, so on and so forth). Then auto nest.
  1. Use Different Nesting Strategies
    1. Don’t just use the auto nest (green button) for the best utilization. Use the yellow auto nest button right next to it. Try different strategies and compare the performance.
  1. Use Tip 1 & 2 In Conjunction With Each Other.
  1. Leave the Computer
    1. Leave the computer while it is performing nesting calculations. Go do other value-added work.
  1. Minimize Part Removal Labor
    1. Move pieces nested with a “score cut” along the boards edge to the very edge thus utilizing the board edge.
  1. Use Scrap and Nest From Previous Jobs
    1. Using the “Reports” feature to identify all the pieces of the last nest. Save all the pieces from the last sheet of the job (assuming it’s a partial nest) and re-nest it at the beginning of the next job – before importing the new job. Import and using the yellow auto-nest button menu. On the “begin nesting on” drop down menu select "First Nest". This will start the current job nesting on the waste from the last job.

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

N. America energy consumption vs. W. Europe

People in the United States and Canada consume 2.4 times as much energy at home as those in Western Europe1. This makes me wonder why the US seems to be the slowest in adopting and enforcing the tighter energy codes. Why does an obvious energy saver such as KoolDuct get turned a blinding eye from those interested in cutting energy cost? We know that its a tried and true technology. Even in the middle east, 50 percent of new construction is insulated foam board. And, why do we as a country complain about energy cost when we do nothing to reduce global and even local demand?

1. Worldwatch Institute, State of the World 2004 Special Focus: The Consumer Society, January 2004,I SBN: 0-393-32539-3

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

KoolDuct tip of the day: tiger closure

Tiger closures are great for the assembling of KoolDuct and allow you not to use the glue. The problem is its almost impossible to bend the tiger closure in a true 90 degree angle. To combat this, bend the tiger as normal then use a dead blow hammer to set the closure. Doing so will bend the tiger over 90 degrees. The duct will be more robust and considerably squarer. Also, the tape will cover the tiger flawlessly.

Currently rated 5.0 by 1 people

  • Currently 5/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

Green is a Pull Through

Green is a Pull Through

“Treehuggers” is a common term I hear from the seasoned in the contracting business. I do not see eye-to-eye with this attitude. Yes, the LEED paperwork and ‘Green’ intercity are work; but not pointless work. As you can read in yesterdays post below there are dollars in this for all. This extra work is not an unpaid extra. It represents business growth for contractors pursue it and total industry growth. I count 23 LEED credits that an HVAC contractor can help a customer achieve. The market is asking for green, governments regs are forcing it1 and economic forces are assisting it2. “Treehugger” carries the connotation of contractors seemly fighting the green movement. My advice is a simple one; when the market asks for something and is willing to pay don’t fight the current. The green movement is a pull through.

  1. Article on new MPG restrictions. Please see http://green.yahoo.com/news/ap/20080423/ap_on_bi_ge/fuel_economy.html

And

http://www.wfaa.com/projectgreen/greenarticles/stories/green080423_ph_fueleconomy.91608a89.html

  1. Resource of Price trends of energy sources.

http://www.doe.gov/pricestrends/index.htm

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

LEED, KoolDuct and the Bottom Line

Here is an artical that I feel our readers will enjoy. Below is just a synopsis. The full article is available at http://www.usgbc.org/News/USGBCInTheNewsDetails.aspx?ID=3637.

 

Title:
CoStar Study Finds LEED, Energy Star Bldgs. Outperform Peers

Author:
Andrew C. Burr

Source:
CoStar Group

Date Written:
3/26/2008

 

"A new study by CoStar Group has found that sustainable "green" buildings outperform their peer non-green assets in key areas such as occupancy, sale price and rental rates, sometimes by wide margins.


The results indicate a broader demand by property investors and tenants for buildings that have earned either LEED® certification or the Energy Star® label and strengthen the "business case" for green buildings, which proponents have increasingly cast as financially sound investments.


According to the study, LEED buildings command rent premiums of $11.24 per square foot over their non-LEED peers and have 3.8 percent higher occupancy.

 

Rental rates in Energy Star buildings represent a $2.38 per square foot premium over comparable non-Energy Star buildings and have 3.6 percent higher occupancy.

And, in a trend that could signal greater attention from institutional investors, Energy Star buildings are selling for an average of $61 per square foot more than their peers, while LEED buildings command a remarkable $171 more per square foot."

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

KoolDuct and the USGBC LEED Accreditation

I have been looking at ways to achieve LEED E.B. credits through the use of KoolDuct. Here are the ones that I found:

 

E.A. Prereq 2: Minimum Energy Performance

E.A. Credit 1: Optimize Energy Performance

E.A. Credit 5.4: Emission Reduction Reporting

E.A. 3.1 – 3.2: Optimize use of IAQ products

 

If anyone can help add to the list please add it to the blog.

More LEED related information please see the US Green Building Council’s website

http://www.usgbc.org/

 

I do know that USGBC used KoolDuct in their headquarter building to help the building be certified to LEED platinum status. Does anyone know how they used it/ what credits did they earn with it?

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

Suggested Link

For anyone that would like to read the research on the topics mentioned here I would suggest this link.

 

http://www.osti.gov/bridge/ 

 

The Information Bridge: DOE Scientific and Technical Information provides free public access to full-text documents and bibliographic citations of Department of Energy (DOE) research report literature. Documents are primarily from 1994 forward and were produced by DOE, the DOE contractor community, and/or DOE grantees. Legacy documents are added as they become available in electronic format.

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

More thoughts on my previous post

We here at GoMech spend a lot of time pondering the world of KoolDuct. During a normal, random, conversation it turned to my previous post. 806 billion kWh is impressive it translated into about $207.78 saved in energy (I’m assuming electrical energy at 8.5 cents per kWh) per person in the US. This is great, but the argument is this is not realistic. I would agree. It would be not only difficult but unfeasible to deconstruct every business and residence in the US and replace it with KoolDuct to pursue these savings. The main point still stands – new construction and renovation should be using this product. The savings does imply a second point. If the US was not so far behind the rest of the world in the use of insulated foam panels, these savings would already be built in the current US infrastructure – more to come.

 

There is also another argument. These savings can be met with other products such as resealing joints with standard duct tape, etc. And again I would agree that this would produce these savings. I hope people do take action on this. Although, people will be missing other savings not implied in my post. These include and not limited to; indoor air quality gains (IAQ), the savings of the insulation (we have only been speaking to the sealing of ducts), install cost and longevity.       

Be the first to rate this post

  • Currently 0/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5

US CO2 savings with KoolDuct

Let me strengthen my argument by first illuminating my bias. I like the product KoolDuct and think everyone renovating or under new construction should be using it. In the following I would like to show you why. The US releases more CO2 than any country in the world (See Figure 1). U.S., homes account for 21% of all CO2 emissions1 and business account for business account for 17% of the total2. Of this release, businesses and residents use a combined total 38% or 2242 million metric tons (in 2001) (see Figure 2)3. The vast majority of energy used in a home is for heating and cooling. According to the DOE, Energy Information Administration's 2001 Residential Energy Consumption Survey anywhere from 38% to 70% of homes energy consumption is spent on heating and cooling4. Businesses data on the energy consumption is estimated to be similar. That leaves between 852 – 1569.4 million metric tons of CO2 being released through heating and cooling. Typical duct systems lose 25 to 40 percent of the heating or cooling energy5. That equates to 213 – 627.6 million metric tons of CO2 leaking out into the environment. Keep in mind that that number is pure waste! This translates in to about 806.68 billion kWh of electrical power per year using the DOE calculator (http://www.epa.gov/grnpower/pubs/calcmeth.htm)6.

 

 

 

  1. U.S. Green Building Council Doubles Local LEED for Homes Network: Press Release. http://www.usgbc.org/News/PressReleaseDetails.aspx?ID=3585. Retrieved 03-31-08
  2. See Energy Information Administration, http://www.eia.doe.gov/oiaf/1605/ggrpt/carbon.html
  3. See Energy Information Administration, http://www.eia.doe.gov/oiaf/1605/ggrpt/carbon.html
  4. U.S. Department of Energy, Energy Information Administration, “Energy Information Administration, 2001 Residential Energy Consumption Survey,” 2001
  5. US Department of Energy. (1999). Improving the efficiency of your duct system.
  6. (http://www.epa.gov/grnpower/pubs/calcmeth.htm)



Currently rated 5.0 by 2 people

  • Currently 5/5 Stars.
  • 1
  • 2
  • 3
  • 4
  • 5